Forschungsbericht 2025
Biomechanik M-3
Leitung: Checa Esteban, Sara
Oberingenieur: Huber, Gerd
Institut auf TORE
Institutswebsite
Publikationen
-
Prospective functional assessment after mandible reconstruction and bone healing assessment - Journal Article
Ruf, Philipp; Duda, Katharina; Fenske, Jakob; Orassi, Vincenzo; Lampert, Philipp; Kreiker, Henri; Checa Esteban, Sara; Heiland, Max; Rendenbach, Carsten; Steffen, Claudius
Clinical Oral Investigations 30 (1): 14 (2026)
Open Access | Publisher DOI
-
Impact of osteotomy angle on bone failure risk in a modified pull-through approach: a finite element analysis - Journal Article
Orassi, Vincenzo; Ruf, Philipp; Hofmann, Elena; Koerdt, Steffen; Kreutzer, Kilian; Nahles, Susanne; Heiland, Max; Rendenbach, Carsten; Checa Esteban, Sara; Neckel, Norbert
BMC Oral Health 25 (1): 1403 (2025)
Open Access | Publisher DOI
-
How does the collar in cementless hip stems work? Comparison of the strain distribution in the cortex of the proximal femur - Journal Article
Brand, Katja; Dakhili, Golzar; Lampe, Frank; Ondruschka, Benjamin; Morlock, Michael; Huber, Gerd
Clinical Biomechanics 130: 106671 (2025)
Open Access | Publisher DOI
-
Fluted stem designs enhance surgical precision and primary stability in cementless revision hip arthroplasty – a cadaver study - Journal Article
Boettcher, Julius M.; Sellenschloh, Kay; Pardos, Ana Cruz; Huber, Gerd; Ondruschka, Benjamin; Morlock, Michael
Clinical Biomechanics 131: 106723 (2026)
Open Access | Publisher DOI
-
Design of surgical impaction instruments matters - Journal Article
Schlieker, Peter; Lampe, Frank; Zwirner, Johann; Ondruschka, Benjamin; Morlock, Michael; Huber, Gerd
Arthroplasty Today 36: 101898 (2025)
Open Access | Publisher DOI
-
Belastung des Hüftgelenks nach Hüftgelenksersatz bei sportlichen Aktivitäten: Geht da noch mehr? Subjektive und Objektive Aspekte - Review Article
Morlock, Michael; Grauer, Georg Friedrich; Damm, Phillip; Böttner, Friedrich
Sportverletzung, Sportschaden (in Press): (2025)
Publisher DOI
-
Parametrized statistical appearance and shape modelling strategy to predict proximal and diaphyseal femoral fractures - Journal Article
Cebeci, Özgür; Cronin, Duane; Checa, Sara
Frontiers in Bioengineering and Biotechnology 13: 1693678 (2025)
Open Access | Publisher DOI
-
Local mechanical stresses can explain the mechanoregulation of bone healing after mandibular reconstruction: an in silico study - Journal Article
Orassi, Vincenzo; Ruf, Philipp; Steffen, Claudius; Duda, Georg; Heiland, Max; Rendenbach, Carsten; Checa Esteban, Sara
Clinical Oral Investigations 29 (11): 518 (2025)
Publisher DOI
-
First-in-human application of dynamic fluoroscopic analysis to quantify intersegmental motion in mandibular free flap reconstruction - Journal Article
Kreiker, Henri; Moewis, Philippe; Steffen, Claudius; Ruf, Philipp; Duda, Georg; Checa Esteban, Sara; Heiland, Max; Fenske, Jakob; Rendenbach, Carsten
Scientific Reports 15 (1): 36482 (2025)
Open Access | Publisher DOI
-
Biomechanical evaluation of shape-optimized CAD/CAM magnesium plates for mandibular reconstruction - Journal Article
Ruf, Philipp; Richthofer, Kilian; Orassi, Vincenzo; Steffen, Claudius; Duda, Georg N.; Heiland, Max; Checa Esteban, Sara; Rendenbach, Carsten
Journal of the Mechanical Behavior of Biomedical Materials 173: 107222 (2026)
Open Access | Publisher DOI
-
An in silico study reveals how architectural and mechanical cues jointly regulate angiogenesis and bone regeneration in 3D printed scaffolds - Journal Article
Dazzi, Chiara; Eichholz, Kian; Freeman, Fiona; Kelly, Daniel; Checa, Sara
Computers in Biology and Medicine 195: 110574 (2025)
Open Access | Publisher DOI
-
Influence of pre-bending on primary fixation stability in one-segmental mandibular reconstruction - Journal Article
Ruf, Philipp; Cebeci, Özgür; Orassi, Vincenzo; Steffen, Claudius; Duda, Georg; Heiland, Max; Checa Esteban, Sara; Rendenbach, Carsten
Computers in Biology and Medicine 196: 110686 (2025)
Open Access | Publisher DOI
-
In silico testing of a multimaterial scaffold for mandibular reconstruction - Journal Article
Rebolo, Pedro; Orassi, Vincenzo; Areias, Bruno; Checa Esteban, Sara; Ramião, Nilza; Correia, Filipe; Rendenbach, Carsten; Natal Jorge Renato; Parente, Marco
Frontiers in bioengineering and biotechnology 13: 1535756 (2025)
Open Access | Publisher DOI
-
Impact of habitual flexion on bone formation after spinal fusion surgery: an In silico study - Review Article
Ananth Swaminathan, Siddarth; Taheri, Nima; Becker, Luis; Pumberger, Matthias; Schmidt, Hendrik; Checa, Sara
Jor Spine 8 (3): e70075 (2025)
Open Access | Publisher DOI
-
Development of an additively manufactured head and neck phantom for computed tomography studies - Journal Article
Wegner, Marie; Hinrichsen, Nina; Rosendahl, Maike; Krause, Dieter; Gargioni, Elisabetta
Transactions on additive manufacturing meets medicine 7(1): 2057 (2025)
Open Access | Publisher DOI
-
Computer-aided scaffold design optimization towards enhanced bone regeneration - Conference Paper
Checa Esteban, Sara
AO Orthopaedic Research Summit 2025
Publisher DOI
-
Letter to the Editor: “Adverse Local Tissue Reaction and Osteolysis After Ceramic-on-Ceramic Total Hip Arthroplasty’’ - Letter to the Editor
Morlock, Michael
Arthroplasty Today 33: 101676 (2025)
Open Access | Publisher DOI
-
Re-revision risk of modular and monobloc revision stems after revision hip arthroplasty - Journal Article
Morlock, Michael; Wu, Y.; Grimberg, Alexander W.; Günther, Klaus-Peter; Perka, Carsten
Bone and Joint Open 6 (1): 1-6 (2025)
Open Access | Publisher DOI
-
Dynamic response of soft tissue can be disregarded during femoral stem impaction - Journal Article
Schlieker, Peter; Lampe, Frank; Zwirner, Johann; Ondruschka, Benjamin; Morlock, Michael; Huber, Gerd
Clinical Biomechanics 125: 106530 (2025)
Open Access | Publisher DOI
-
Effects of nucleotomy on segmental flexibility: a numerical analysis - Journal Article
Bashkuev, Maxim; Schmidt, Hendrik; Checa Esteban, Sara; Reitmaier, Sandra
Journal of Biomechanics 184: 112669 (2025)
Open Access | Publisher DOI
-
Vibratory and conventional impaction of acetabular components into porcine acetabula - Journal Article
Niki, Yasaman; Huber, Gerd; Behzadi, Kambiz; Morlock, Michael
Bone and Joint Research 14 (4): 306-314 (2025)
Open Access | Publisher DOI
-
A modified Wagner stem design Increases the primary stability in cementless revision hip arthroplasty - Journal Article
Böttcher, Julius; Sellenschloh, Kay; Huber, Gerd; Ondruschka, Benjamin; Morlock, Michael
Arthroplasty Today 32: 101622 (2025)
Open Access | Publisher DOI
-
Biomechanik der Hüft-Revisionsendoprothese - Doctoral Thesis
Böttcher, Julius M.
Shaker 978-3-8191-0112-0: (2025)
-
Experimental determination of the stabbing intensity in an intracranial stabbing death - Journal Article
Zwirner, Johann; Vollmer, Matthias; Scholze, Mario; Anders-Lohner, Sven; Morlock, Michael; Ondruschka, Benjamin
International Journal of Legal Medicine 140: 1113-1120 (2026)
Open Access | Publisher DOI
-
Einfluss der Schaftgeometrie einer zementfreien Primärprothese auf Beanspruchungen am proximalen Femur während der Implantation – Eine numerische Analyse - Master Thesis
Harpeng, Theresa Magdalena
Technische Universität Hamburg (2025)
Open Access
Projekte
-
SFB 1444 - Teilprojekt P10: Räumlich-zeitliche Regulierung der sprossenden Angiogenese durch kombinierte mechanische und geometrische Anreize
Deutsche Forschungsgemeinschaft (DFG); Laufzeit 2025-2028
Projektleitung: Checa Esteban, Sara
Externe beteiligte Einrichtungen: Charité – University Medicine Berlin
-
Identification of the force flow in a collared implant for static, dynamic and accidental load cases
DePuy International Limited; Laufzeit 2023-2025
Projektleitung: Huber, Gerd; Morlock, Michael
Co-Projektleitung: Glismann, Katja
-
The influence of patient positioning and fixation during surgery on mechanical impedance during implantation
DePuy International Limited; Laufzeit 2023-2025
Projektleitung: Huber, Gerd; Morlock, Michael
Co-Projektleitung: Schlieker, Peter
-
The Contact Situation of Revision Hip Stems
DePuy International Limited; Laufzeit 2023-2025
Projektleitung: Huber, Gerd; Morlock, Michael
Co-Projektleitung: Böttcher, Julius
Großgeräte
- 3D Koordinaten Messmaschine
Hersteller: Mitutoyo
DOI: 10.15480/882.14110
DFG-Geräteklassifikation: 8700 -- Koordinaten-Messmaschinen (mechanisch)
- Alicona, InfiniteFocus Microskopie
Hersteller: Alicona Imaging GmbH
DOI: 10.15480/882.14108
DFG-Geräteklassifikation: 4150 -- Oberflächen-Prüfgeräte (Profil,Rauhtiefe)
- ARTEC 3D Handscanner
Hersteller: ARTEC
DOI: 10.15480/882.14112
DFG-Geräteklassifikation: 5360 -- Messgeräte für gestreutes und reflektiertes Licht, optische Oberflächenprüfung
- C-Bogen
Hersteller: Philips
DOI: 10.15480/882.14182
DFG-Geräteklassifikation: 3200 -- Digitale Röntgenanlagen (außer Angiographie)
- Creaform 3D-Handscanner
Hersteller: AMETEK GmbH
DOI: 10.15480/882.14100
DFG-Geräteklassifikation: 5360 -- Messgeräte für gestreutes und reflektiertes Licht, optische Oberflächenprüfung
- Digitalmikroskop VHX 7000
Hersteller: Keyence Deutschland GmbH
DOI: 10.15480/882.14101
DFG-Geräteklassifikation: 5000 -- Labormikroskope
- Druckmessplatte pedar-x
Hersteller: novel
DOI: 10.15480/882.14111
DFG-Geräteklassifikation: 8350 -- Druckmessgeräte (außer 3000 und 8970)
- GOM ARAMIS 3D Camera 6M Professional Line
Hersteller: Carl Zeiss GOM Metrology GmbH
DOI: 10.15480/882.14181
DFG-Geräteklassifikation: 0620 -- Elektrooptische Distanzmesser (Geodäsie)
- Laserscanningmikroskop VK-X 150
Hersteller: Keyence Deutschland GmbH
DOI: 10.15480/882.14105
DFG-Geräteklassifikation: 5000 -- Labormikroskope
- Micro CT 35
Hersteller: Scanco Medical AG
DOI: 10.15480/882.14102
DFG-Geräteklassifikation: 4070 -- CT-(Computertomographie-) Geräte (Röntgen-Tomographie) für Materialwissenschaft
- MTS Universalprüfmaschine 858 Mini Bionix II, zweiachsig
DOI: 10.15480/882.14099
DFG-Geräteklassifikation: 2910 -- Universal-Prüfmaschinen (Zug-, Druck-, dynamisch, statisch)
- MTS Universalprüfmaschine BIONIX, zweiachsig
Hersteller: MTS
DOI: 10.15480/882.14103
DFG-Geräteklassifikation: 2910 -- Universal-Prüfmaschinen (Zug-, Druck-, dynamisch, statisch)
- Spindelprüfmachine Zwick/Roell Z010
Hersteller: Zwick GmbH Werkst. Prüfmasch.
DOI: 10.15480/882.14104
DFG-Geräteklassifikation: 2910 -- Universal-Prüfmaschinen (Zug-, Druck-, dynamisch, statisch)
- Spindelprüfmaschine Zwicki 1120
Hersteller: Zwick GmbH Werkst. Prüfmasch.
DOI: 10.15480/882.14106
DFG-Geräteklassifikation: 2910 -- Universal-Prüfmaschinen (Zug-, Druck-, dynamisch, statisch)
- Vicon Bewegungsanalyse, 6 Kameras
Hersteller: VICON
DOI: 10.15480/882.14109
DFG-Geräteklassifikation: 0620 -- Elektrooptische Distanzmesser (Geodäsie)
- Wärme / Brutschrank WB120
Hersteller: Binder
DOI: 10.15480/882.14107
DFG-Geräteklassifikation: 3510 -- Brutschränke, Lichtthermostaten, Gewebekulturgeräte